Rheomat RM100 Plus
Rotational Viscometer acc. to
TS 5833 EN ISO 3219
(Determination of viscosity using a rotational viscometer with defined shear rate)
TS 6126 EN ISO 2555
(Determination of apparent viscosity by the brookfield test method)
TS EN ISO 2884-1 Paints and varnishes -- Determination of viscosity using rotary viscometers -- Part 1: Cone-and-plate viscometer operated at a high rate of shear
TS 5809 - ASTM D 562 Krebs-Stormer (KU) method
RM100 Plus high speed viscometer is designed for "real viscosity" measurements under high shear rates according to ISO 3219 (DIN11-22-33). Due to its modular design, the instrument is also capable to work with different measuring systems including ASTM D 562 / TS 5809 (Krebs-Stormer), ASTM / ISO 2555 (RV), "MS-R1 to 5" or "MS-BV 1-1000". Together with EVA-CP Temperature Control Stand, the unit can also be used as an ICI Cone & Plate Viskometer. RM100 has a maximum speed of 1500rpm which allows creating shear rates more than 10.000 s-1 depending on the measurement geometry.
Its modern springless technology and sturdy design ensures undeniable reliability. The RM100 PLUS has a 7” touch screen and comes with a stylus. This easy-to-use screen lets you see all measurement parameters at the same time. Unlike other Krebs viscometers which can only measure up to 141KU which is defined in old ASTM D 562 standard, RM 100 Plus has a wide torque range which makes it also capable of Krebs-Stormer measurements of the high viscosity paints without switching other measuring system or spindle. With extrapolation of the standard KU curve, measurements up to 250 KU is possible.
RM 100 Plus has a integrated temperature sensor and it is delivered with a laboratory stand but without measuring system. Required measuring system or systems shall be ordered individually.
RM100 Plus, also has a LR Version which allows higher accuracy for determination of the appearent viscosity of low viscosity liquids. Instruments come with a calibration certificate.
One Instrument
Multi Measuring System
Lamy Viscometers designed and manufactured to run with different measuring systems. The RM100 PLUS is capable of measuring both appearent viscosity measurement acc. to ISO2555, ISO3219, ISO2884-1 ICI Cone & Plate and MS-BV1-1000 measuring systems as well as KU measurements acc. to ASTM 562 - TS 5809 Krebs-Stormer Method used in paint industry.
Springless Design
Lamy Viscometers does not contain any spring for torque measurements. This innovative design allows measurements without being effected by the ambient temperature and also avoids the necessity of precise leveling of the instrument. RM100 Touch is designed for tough industrial enviroments as well as fine laboratory conditions.
Kinematic Viscosity Measurements
Lamy Viscometers allows product density input making the kinematic viscosity measurements possible. Devices lets you set measuring times for thixotropic products.
RM100 Plus Specifications
LR Version : 0,005 to 0.8 mNm
With KU System: 40-~250KU
Hardened steel stand: L280 x W200 x H30 mm
Stainless steel rod: 500 mm
Weight: 6.7 kg
with easy mount bayonet coupling
without measuring system
with easy mount AC115 coupling
without measuring system
with easy mount AC265 coupling
without measuring system
with measuring system MS-R 2-3-4 in case
With CP1 temperature control stand (5 to 80°C) and one selected cone spindle
With CP1H high temperature control stand (ambiant to 300°C) and one selected cone spindle
with measuring system MS-R 1-2-3-4-5 in case
Measuring Systems
Stainless steel discs measuring system for relative viscosity measurements in a 600-ml beaker. This system is used for measurements in accordance with the ASTM-ISO 2555 standard.
It is supplied as standard on the Black One (MS 2 to 7) and can also be used with the Rheomat First RM, RM 100 and RM 200.
This measuring system is widely used in coating industry to determine the viscosity of paints, varnishes and other coatings in grams or Kreps-Unit (KU) in accordance with ASTM D562.
Together with viscometer B-One Touch or First RM Toch, standard range of 40-141KU is measurable while with high torque range of RM100 allows you to measure the products with viscosities up to ~250KU. To measure the viscosities of putties and pastes, a low torque "paste spindle" is also available for all BO, First RM and RM100.
Coaxial cylinder measuring system according to the DIN / ISO 3219 standard. Each component: bob, tube and cap can be bought and used separately, depending on using or product requirements.
MS-DIN measuring systems could be thermostated with thermostatisation cell DIN / ISO 3219 or EVA MS-DIN. It can be used with the First Touch, RM 100 Touch and RM 200 Touch.
Stainless steel discs measuring system for viscosity measurements in a 150 ml Beaker. This system allows rapid and economical measurements.
This system could be used by First Touch and can also be used with the Rheomat RM 100 Touch & RM 200 Touch
complete with carrying case
Paddle measuring system. It was already fitted to the TV EPPRECHT type viscometers,and has been recognised as the standard for numerous viscosity measurements in the cosmetic and paint industries. It is also perfectly suited for measuring the viscosity of heterogeneous products, or fluids containing lumps, for example, in the food and beverage or mineral chemistry industries.
TV Epprecht MS-R 1-5 measuring system can be thermostated via EVA MS-R Constant Temperature Stand whic can accommodate 2 instruments allowing you to fully optimise your workspace. This measuring system is compatible with Rheomat RM100 Touch and RM200 Touch.
This measuring system is used in foods , sealants and cosmetics to provide information on yield behaviour at low rotational rates.
This measuring system owns two coaxial cylinders and it could be determine easily the dynamic viscosity and the yield value at 300 and 600 rpm, according A.P.I. standard, on drilling fluids, it could be also measure the "gel" value at 3 rpm.
Fann Measuring System is compatible with RM 100 Touch and RHEOMAT RM 200 Touch and also the portable viscometer RM 100 P Touch.
This coaxial cylindrical measuring system was one of the first to granted OICCC certification in 1970 to check chocolate rheology using the Casson method.
It continues to be the most universal measuring system for very fluid couverture chocolate to more viscous “block” type products and fillings.
Cone & Plate measuring system consists of a conical spindle on a thermostated plate which is perfectly adapted to rheological control on small volume of sample and to the quick change of temperature. From 5°C to 300°C range different type of themostatic plate stands are avaiable.
Cone & plate measuring system is also ideal for viscosity measurement of high viscosity products under high shear rates. Melting viscosity determination of the powder coatings is another aplication field of the Cone & Plate System
RT-3 Measuring System is designed for viscosity measurements at high temperatures up to 300°C. Either runs with MB-B, C or D spindles in disposable aluminium cups or with cone spindles on heated plate as a ICI Cone/Plate system together with high temperature electric oven stand: RT-3.
RT-3 High Temperature Viscosity Measuring system provides thermostating from room temperature up to 300°C It can be used with the First Touch, RM 100 Touch and RM 200 Touch.
Associated to RM300 speed imposed rheometer, those measuring systems using small sample volumes, assure rheological measurement in a greater type of applications. Systems includes coaxial bob/pipe or Spindles for "Cone & Plate" system both according to DIN / ISO 3219. Each Component: spindle, cylinder pipe or cap can be individually supplied due to measurement or product requirements.
Measuring System is compatible with discontinued models like Rheomat RM115, RM260 or RM300 as well as AC115 socket type universal speed imposed rheometer "Rheomat RM200 TOUCH".
EVA Temperature Control Stands
Thermostated unit by Peltier Effect for coaxial systems without circulating fluid.
Ideal for rheological measurement that needs fast Temperature changes.
Use your FIRST TOUCH, RM100 TOUCH or RM200 TOUCH in conjunction with eva ms-din to achieve thermostatic measurement results of your samples.
EVA-DIN Specifications
Thermostated unit by Peltier Effect for anchor type systems without circulating fluid.
Ideal for rheological measurement that needs fast Temperature changes. The EVA MS-R system can accommodate 2 instruments, allowing you to fully optimise your workspace. With the EVA MS-R system, you have the option of having 9 samples on the Peltier thermostated plate.
Use your RM100 TOUCH or RM200 TOUCH in conjunction with EVA MS-R to achieve thermostatic measurement results of your samples.
EVA MS-R Specifications
Thermostated unit by Peltier Effect for 600 ml Becher used in ASTM / ISO 2555 (Determination of apparent viscosity by the Brookfield Test method) Standard Viscosity measurement.
Ideal to control and adjust the Temperature of samples contained in 600 Becher imposed in ASTM / ISO 2555 Standard viscosity measurement. This system is quick to heat or cool the vessel and it don't used any fluid.
EVA MS-ASTM/ISO2555 could be associated to FIRST TOUCH , RM 100 TOUCH and RM 200 TOUCH.
EVA MS-LR Specifications
Low cost electrical oven for viscosity measurements at high temperatures. The temperature range of RT-1 is from ambiant temperature to 300°C. It uses coaxial geometries standardised according DIN/ISO 3219 ans also aluminium disposable cups geometry MS-C.
The RT-1 high-temperature oven can accommodate your FIRST Touch, RM100 Touch or RM200 Touch.
RT-1 Specifications
This stand, thermostated by Peltier Effect works from 5 to 80°C without circulating fluid and from -20°C to 120°C when it is associated to a circulating bath (CP1 Fluid).
It enables rheological measurement on very small quantity of sample and heat and cool very quickly for rapid measurements. Its stable up and down arm assure a perfect positioning of cone in sample.
CP1 standı FIRST Touch, RM100 Touch ya da RM200 Touch viskometreleri ve reometreleriyle kullanılabilir.
CP-1 Specifications
Special Thermostating Oven Stand for viscosity measurements.It is using aluminium disposable cups, MB-B, C or D, and cone-plate geometries from ambient to 300°C. It could be associated with an inside programmer to realise ramp or steps of temperature automatically.
Pair your FIRST Touch, RM100 Touch or RM200 Touch to the RT-3 high temperature oven and carry out your measurements with precision.