The Surfix® S portable coating thickness gauge with its exchangeable probes is designed for fast, practical and precise Coating Thickness Measurement. Depending on the selected probe, it can be used for all types of varnish, paint and electroplated coatings on iron and steel as well as varnish, paint and anodising coatings on non-ferrous metals and on austenitic stainless steels.
A wide range of interchangeable probes provides many options for universal as well as special measurement tasks. It includes one of the world’s smallest measuring sensors which guarantees reliable measurements even on difficult geometries.
F-type probes operates only with the magnetic method (TS 2311 EN ISO 2178) to measure the coating thickness on ferrous substrates like steel and iron, N-types probes measures only with the eddy current method (TS 2674 EN ISO 2360) in order to measure on non-ferrous surfaces like aluminium, brass, zinc, etc. FN-type probes operates both with magnetic method and the eddy current method to ensure operation on all kind of metals.
Surfix-S has three different types: Standard ,Pro and Basic. When used with a FN probe, all three types has a substrate recognition function which makes the Fe / NFe selection fully automatic right after positioning the probe on the surface, which also can be set manually. Standard types provides also statistical data (N, Avg, Std. Dev., Min, Max) over a number of measurements. Statistical data can be transferred to PC over IR Interface for documentation.
Surfix Pro-S also provides statistical data (N, Avg, Std. Dev., Min, Max) up to 10000 measurements in max. 250 nameable batch files. Statistical data can be transferred to PC over IR or RS 232 interface for documentation. Optional Software Prosoft is also available. It also allows 2 foil calibration in order to produce most accurate measurements.
Surfix® Pro-S is ideal for speedy, non-destructive and exceptionally precise Coating Thickness Measurement measurement:
- in paintshops and for electroplaters
- for wet and powder coating operations
- in the automobile/automobile parts industry
- for incoming material inspection, during production and for final inspection procedures
- in development engineering and expert assessment
- in laboratory and field operations.
Dry Film Thickness Gauge (without probe - probe needs to be ordered seperately)
Range: 0-30.000 µm (depending on the selected probe)
Resolution: 0.1 µm or <0.2% of measurement(depending on the selected probe)
Accuracy: ± 0,7µm / 3µm (depending on the selected probe)
Calibration: Factory Calibration + Zero Calibration + Foil Calibration + offset-function: add. or subtract. of a constant value
Memory: 200 measurements + Statistics (N, Avg, Std. Dev., Min, Max)
Dry Film Thickness Gauge (without probe - probe needs to be ordered seperately)
Range: 0-30.000 µm (depending on the selected probe)
Resolution: 0.1 µm or <0.2% of measurement(depending on the selected probe)
Accuracy: ± 0,7µm / 3µm (depending on the selected probe)
Calibration: Factory Calibration + Zero Calibration + Foil Calibration + offset-function: add. or subtract. of a constant value
Memory: Yok
Dry Film Thickness Gauge (without probe - probe needs to be ordered seperately)
Range: 0-30.000 µm (depending on the selected probe)
Resolution: 0.1 µm or <0.2% of measurement(depending on the selected probe)
Accuracy: ± 0,7µm / 3µm (depending on the selected probe)
Calibration: Factory Calibration + Zero Calibration + 1 Foil Calibration + 2 Foil Calibration + offset-function: add. or subtract. of a constant value
Memory: 10.000 measurements in 250 batches + Statistics (N, Avg, Std. Dev., Min, Max)
For measuring on Fe (steel/iron) and NFe (Aluminium, Brass, Zinc Etc.) metals
Range: 0-200 µm
Accuracy: ± 0,7µm + 1% of reading
For measuring on Fe (steel/iron) and NFe (Aluminium, Brass, Zinc Etc.) metals
Range: 0-1.500 µm
Accuracy: ± 1µm + 1% of reading
For measuring on Fe (steel/iron) and NFe (Aluminium, Brass, Zinc Etc.) metals
Range: 0-1.500 µm
Accuracy: ± 1µm + 1% of reading
For measuring on Fe (steel/iron) and NFe (Aluminium, Brass, Zinc Etc.) metals
Range: 0-1.500 µm
Accuracy: ± 1µm + 1% of reading
For measuring on Fe (steel/iron) and NFe (Aluminium, Brass, Zinc Etc.) metals
Range: 0-1.500 µm
Accuracy: ± 1µm + 1% of reading
For measuring on Fe (steel/iron) and NFe (Aluminium, Brass, Zinc Etc.) metals
Range: 0-3.500 µm
Accuracy: ± 2µm + 1% of reading
For measuring on Fe (steel/iron) metals
Range: 0-1.500 µm
Accuracy: ± 1µm + 1% of reading
For measuring on Fe (steel/iron) metals
Range: 0-1.500 µm
Accuracy: ± 1µm + 1% of reading
For measuring on Fe (steel/iron) metals
Range: 0-3.500 µm
Accuracy: ± 2µm + 1% of reading
For measuring on Fe (steel/iron) metals
Range: 0-10.000 µm
Accuracy: ± 3µm + 1% of reading
For measuring on NFe (Aluminium, Brass, Zinc Etc.) metals
Range: 0-1.500 µm
Accuracy: ± 1µm + 1% of reading
For measuring on NFe (Aluminium, Brass, Zinc Etc.) metals
Range: 0-1.500 µm